12V 150Ah Deep Cycle Gel Battery Energy Storage Solar System UPS
Description
Deep Cycle Gel Battery has better performance than the valve regulated sealed lead-acid battery, strong adaptability to ambient temperature (high and low temperature), ability to withstand long time discharge, cyclic discharge, deep discharge and high current discharge, overcharge and over discharge self-protection, etc. Gel agent for gel battery is fumed silica, fumed silica is a high-purity white odorless nano-powder material with thickening, anti-caking, controlling system rheology and thixotropy, etc. In addition to the traditional application, Deep Cycle Gel Battery has been widely used in colloidal battery in recent years.
Model | Nominal Voltage | Capacity C10 | Weight | Dimension | ||
Height | Length | Width | ||||
V | Ah | kg | mm | mm | mm | |
LCPC 7-12 | 12 | 7 | 2.3 | 101 | 151 | 65 |
LCPC 12-12 | 12 | 12 | 3.8 | 103 | 151 | 99 |
LCPC 17-12 | 12 | 17 | 5.5 | 165 | 181 | 76 |
LCPC 24-12 | 12 | 24 | 7.2 | 126 | 176 | 166 |
LCPC 33-12 | 12 | 33 | 9.5 | 160 | 195 | 130 |
LCPC 38-12 | 12 | 38 | 11.8 | 175 | 196 | 165 |
LCPC 50-12 | 12 | 50 | 15.7 | 212 | 227 | 138 |
LCPC 65-12 | 12 | 65 | 19.2 | 174 | 350 | 166 |
LCPC 70-12 | 12 | 70 | 21.0 | 212 | 260 | 168 |
LCPC 80-12 | 12 | 80 | 24.0 | 220 | 331 | 176 |
LCPC 100-12 | 12 | 100 | 28.8 | 220 | 331 | 176 |
LCPC 120-12 | 12 | 120 | 33.8 | 235 | 406 | 174 |
LCPC 150-12 | 12 | 150 | 41.5 | 240 | 483 | 170 |
LCPC 200-12 | 12 | 200 | 56.7 | 228 | 522 | 240 |
LCPC 250-12 | 12 | 250 | 70.5 | 228 | 522 | 268 |
Product Features
Advantages
Application
Compliant standards
Use of Deep Cycle Gel Battery
Discharge: 1) 12V battery charging and discharging, 250Ah battery with a current of no more than 25A for 10 hours to discharge until the battery termination voltage of 10.8V or more, do not over discharge.
2) During the discharge process, measure and record the battery voltage, discharge current and ambient temperature every hour, pay attention to the change of ammeter and battery voltage at any time, when the voltage drops to about 12.0V, change to half an hour test. When the measured voltage is 10.8v, stop discharging, open the discharge switch, the discharge is over. And record the discharge termination time, battery voltage, ambient temperature.
3) After discharge, the battery should be recharged in time, to prevent acidification of the poles, the discharge-charging interval should not exceed 8 hours, so it must be balanced within 8 hours to replenish the electricity, the average charging voltage is set to 14.1V (the average of the measured value of the positive and negative terminals of the battery at 25℃), and the maximum charging current is set to 0.25C10A. The battery will run normally with the float charging voltage of 13.5V. Battery 13.5V.
4) After discharge, check the discharge capacity at 25℃, it should be not less than 85% of the rated capacity, i.e. 12V250AH battery is not less than 212.5Ah.